LC1D50AM7C
1
  • LC1D50AM7C
2
views: 229

LC1D50AM7C

Rate:
0.0000/5

( 0 reviews )

Item NO.: V008466 MOQ: 0
Weight:    1kgs
Package Size:  
 Price:
$32.00
 Qty:
      $32.00
 Shipping:   Calculate Shipping Cost

ZLL

LC1D50AM7C  

delivery time:in stock



Main
Range TeSys
TeSys Deca
Range of Product TeSys D
TeSys Deca
Product or Component Type Contactor
Device short name LC1D
Contactor application Resistive load
Motor control
Utilisation category AC-4
AC-1
AC-3
AC-3e
Poles description 3P
[Ue] rated operational voltage Power circuit <= 690 V AC 25...400 Hz
Power circuit <= 300 V DC
[Ie] rated operational current 50 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit
80 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
50 A 140 °F (60 °C)) <= 440 V AC AC-3e power circuit
[Uc] control circuit voltage 24 V AC 50/60 Hz
Complementary
motor power kW 15 kW 220...230 V AC 50/60 Hz AC-3)
22 kW 380...400 V AC 50/60 Hz AC-3)
30 kW 500 V AC 50/60 Hz AC-3)
33 kW 660...690 V AC 50/60 Hz AC-3)
25 kW 415 V AC 50/60 Hz AC-3)
30 kW 440 V AC 50/60 Hz AC-3)
11 kW 400 V AC 50/60 Hz AC-4)
15 kW 220...230 V AC 50/60 Hz AC-3e)
22 kW 380...400 V AC 50/60 Hz AC-3e)
30 kW 500 V AC 50/60 Hz AC-3e)
33 kW 660...690 V AC 50/60 Hz AC-3e)
25 kW 415 V AC 50/60 Hz AC-3e)
30 kW 440 V AC 50/60 Hz AC-3e)
Maximum Horse Power Rating 3 hp 115 V at AC 50/60 Hz for 1 phase
7.5 hp 230/240 V at AC 50/60 Hz for 1 phase
15 hp 200/208 V at AC 50/60 Hz for 3 phase
15 hp 230/240 V at AC 50/60 Hz for 3 phase
40 hp 460/480 V at AC 50/60 Hz for 3 phase
40 hp 575/600 V at AC 50/60 Hz for 3 phase
Compatibility code LC1D
Pole contact composition 3 NO
Contact compatibility M2
Protective cover With
[Ith] conventional free air thermal current 10 A 140 °F (60 °C) signalling circuit
80 A 140 °F (60 °C) power circuit
Irms rated making capacity 140 A AC signalling circuit IEC 60947-5-1
250 A DC signalling circuit IEC 60947-5-1
900 A 440 V power circuit IEC 60947
rated breaking capacity 900 A 440 V power circuit IEC 60947
[Icw] rated short-time withstand current 400 A 104 °F (40 °C) - 10 s power circuit
810 A 104 °F (40 °C) - 1 s power circuit
84 A 104 °F (40 °C) - 10 min power circuit
208 A 104 °F (40 °C) - 1 min power circuit
100 A - 1 s signalling circuit
120 A - 500 ms signalling circuit
140 A - 100 ms signalling circuit
associated fuse rating 10 A gG signalling circuit IEC 60947-5-1
100 A gG <= 690 V type 1 power circuit
100 A gG <= 690 V type 2 power circuit
average impedance 1.5 mOhm - Ith 80 A 50 Hz power circuit
power dissipation per pole 3.7 W AC-3
9.6 W AC-1
3.7 W AC-3e
[Ui] rated insulation voltage Power circuit 600 V CSA
Power circuit 600 V UL
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
Power circuit 690 V IEC 60947-4-1
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 6 kV IEC 60947
safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability 6 Mcycles
electrical durability 1.45 Mcycles 50 A AC-3 <= 440 V
1.1 Mcycles 80 A AC-1 <= 440 V
1.45 Mcycles 50 A AC-3e <= 440 V
control circuit type AC 50/60 Hz standard
Coil technology Without built-in suppressor module
control circuit voltage limits 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz
0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz
0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz
1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz
inrush power in VA 140 VA 60 Hz 0.75 68 °F (20 °C))
160 VA 50 Hz 0.75 68 °F (20 °C))
hold-in power consumption in VA 13 VA 60 Hz 0.3 68 °F (20 °C))
15 VA 50 Hz 0.3 68 °F (20 °C))
heat dissipation 4…5 W 50/60 Hz
operating time 4...19 ms opening
12...26 ms closing
maximum operating rate 3600 cyc/h 140 °F (60 °C)


 
No comment
Total 0 records, divided into1 pages. First Prev Next Last
View History
Related tools
$39.00
$88.00
$1205.00
$346.00
$1162.00
$7.50
$44.00
Business time
9:00-22:00
  • Email:support@rig123.com